Elk Products M1EZ8 Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Numerické klávesnice Elk Products M1EZ8. Elk Products M1EZ8 User guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - USER GUIDE

USER GUIDECross Platform ControlThis Guide covers the operationof the M1 and M1EZ8 Controller modelsTML519 Rev. G 05/07

Strany 2

M1 Cross Platform Controllers - User GuidePage 10Bypassing Zones(Optional) Manual bypassing of a zone will exclude it from the system for theimmediat

Strany 3 - TABLE OF CONTENTS

M1 Cross Platform Controllers - User GuidePage 11Disarming and Resetting the SystemAfter entering the premises through one of the assigned Entry delay

Strany 4 - Understanding The Keypad

M1 Cross Platform Controllers - User GuidePage 12Alarm AcknowledgmentsAfter an alarm has been silenced by a valid user code, the display willcontinue

Strany 5

M1 Cross Platform Controllers - User GuidePage 13Chime Mode, Turning On and OffChime is a function which can provide an audible alert whenever certain

Strany 6 - System Notes

M1 Cross Platform Controllers - User GuidePage 14Keypad MenusThis section explains the use of the most commonly used keypad menus. Foradditional inst

Strany 7 - Operating The System

M1 Cross Platform Controllers - User GuidePage 152-LIGHTING Provides the ability to view and control lights or appliance typedevices. Each lighting

Strany 8 - Arming in the “Stay” Mode

M1 Cross Platform Controllers - User GuidePage 165-KEYPAD TEMPERATURE SENSORS Provides the ability to select andview the temperature sensor inside a

Strany 9 - Using the Quick Arm

M1 Cross Platform Controllers - User GuidePage 17Menu 3-Walk Test Area (zones)Permits a local test of all zones assigned to the system/area. No alarm

Strany 10 - Bypassing Zones

M1 Cross Platform Controllers - User GuidePage 18Menu 5-View (Zone) StatusThis allows a comprehensive viewing of the status for all area zones1. Press

Strany 11

M1 Cross Platform Controllers - User GuidePage 19Menu 7-Automation Custom Settings(Requires Master Level User Code) The installer can assign certain a

Strany 12 - Troubles

M1 Cross Platform Controllers - User GuidePage 2This system consists of a main control unit, one or more keypads, and various contactsensors and detec

Strany 13

M1 Cross Platform Controllers - User GuidePage 20 84-SYSTEM TESTS Allows Battery Test, LCD Test, & Communicator Test.Option 1: Battery Test Pla

Strany 14 - Keypad Menus

M1 Cross Platform Controllers - User GuidePage 21Operation Via TelephoneThe system may be optionally controlled from a Telephone using push-button“ton

Strany 15

M1 Cross Platform Controllers - User GuidePage 22For Zone Status press 4. If the system is not ready this menu can be usedto hear the status of any v

Strany 16 - Menu 2-Reset Smoke Detectors

M1 Cross Platform Controllers - User GuidePage 23Fire Safety & MaintenanceIf the fire alarm activates, the siren or bell will pulse ON and OFF and

Strany 17 - Menu 4-View History Log

M1 Cross Platform Controllers - User GuidePage 24Emergency Evacuation PlansPreparation of an evacuation plan Is of prime importance in fire prevention

Strany 18 - Menu 5-View (Zone) Status

M1 Cross Platform Controllers - User GuidePage 25System TestingTo assure the proper working order, it is recommended that the system betested once a

Strany 19 - Menu 8-System Settings

M1 Cross Platform Controllers - User GuidePage 26FCC Statements (Part 15 & 68)The ELK-M1 complies with Part 68 of the FCC rules. On the front name

Strany 20

M1 Cross Platform Controllers - User GuidePage 27GlossaryArea (Partition): A room or section of a building having at least one Keypadand one or more

Strany 21 - Operation Via Telephone

www.elkproducts.comPrinted in USA

Strany 22

M1 Cross Platform Controllers - User GuidePage 3TABLE OF CONTENTSUnderstanding The Keypad ...

Strany 23 - Fire Safety & Maintenance

M1 Cross Platform Controllers - User GuidePage 4Understanding The KeypadReady Light - ON when all burglar zones are secure and the system is OK to arm

Strany 24 - Emergency Evacuation Plans

M1 Cross Platform Controllers - User GuidePage 5Emergency Activation Keys (if enabled)Fire - If enabled, this key activates the local fire alarm audib

Strany 25 - System Testing

M1 Cross Platform Controllers - User GuidePage 6System NotesCentral Monitoring Station: _______________________________ Acct. # ______Installation Co

Strany 26

M1 Cross Platform Controllers - User GuidePage 7Operating The SystemRead this entire section before attempting to operate the system.User Codes<>

Strany 27 - Glossary

M1 Cross Platform Controllers - User GuidePage 8Arming in the “Away” ModeAway mode arming is the highest arm level, intended for use when thepremises

Strany 28 - Printed in USA

M1 Cross Platform Controllers - User GuidePage 9Auto Stay Arming(Optional) If this feature was enabled by your installer, it will automaticallychange

Komentáře k této Příručce